Stronger than the backwater: The Pumpfix S Underfloor is the only basement drain with a backwater valve that pumps against backwater. It normally disposes of wastewater without sewage continuously via the free slope to the sewer – even in the event of a burst water pipe or flooding. Yet it shows its true strength in the event of backwater: The pump then switches on automatically and the Pumpfix S Underfloor drains reliably, even against the backwater pressure. It is also ideally suited for draining outdoor basement stairs.
The Pumpfix S Underfloor is available in two versions: a compact version with a polymer cover, which is particularly suitable for renovation projects, and a larger version with numerous connection options and a tileable surface.
The Pumpfix S Underfloor basement drain normally uses the natural slope to the sewer. The continuous disposal of wastewater is also possible in the event of a burst water pipe or flooding. In the event of backwater, the pump switches on automatically and drains reliably, even against the backwater pressure.
In addition to the inlet option via the cover, several horizontal inlets can also be attached, for example, for a shower, washing machine and washbasin (Drilling open the drain body allows connections of up to DN 100 to be fitted, above the compression flange and in the upper section up to DN 70). The Pumpfix S Underfloor basement drain can therefore also be used as central backwater protection.
The KESSEL sealing set for installation in waterproof concrete ensures reliable protection against ground water. The extension section with a central flange and elastomeric waterproofing membrane enable implementation also in deeper installation situations.
The radioactive noble gas radon is a natural element that is present virtually everywhere in our earth's crust. If it accumulates in a high concentration within enclosed spaces, it can be hazardous to humans: Radon is considered an environmental risk factor for lung cancer. The Pumpfix S Underfloor for floor slab installation helps to prevent this health hazard from entering buildings. The backwater valve has been tested and certified as radon-proof.
Features & benefits
- Automatic pump activation during backwater events — drains even against backwater pressure
- Dual-mode operation: gravity flow under normal conditions, pumped drainage during backwater
- Handles continuous wastewater disposal even in the event of a burst water pipe or flooding
- Suitable for draining outdoor basement stairs
- Multiple horizontal inlet connection options (shower, washing machine, washbasin)
- Drill-open drain body allows connections up to DN 100 (above compression flange) and up to DN 70 in upper section
- Can be used as central backwater protection for multiple drainage points
- Available in two versions: compact polymer cover (ideal for renovations) and tileable cover with numerous connection options
- Compatible with waterproof concrete installation via KESSEL sealing set
- Extension section with central flange and elastomeric waterproofing membrane for deeper installation situations
- Backwater valve tested and certified as radon-proof
- GTF 500 pump with documented performance curve
Applications
- Basement floor slab installation
- Outdoor basement stair drainage
- Central backwater protection for multiple drainage points (shower, washing machine, washbasin)
- Renovation projects (compact version with polymer cover)
- Waterproof concrete installations
- Properties at risk of backwater or flooding
Technical specifications
| Pump model | GTF 500 |
|---|---|
| Nominal size (DN) | DN 100 |
| Installation depth | 330 mm |
| Length | 485 mm |
| Width | 380 mm |
| Backwater protection type | Type 5 |
| Max connection size (drain body) | DN 100 |
| Max connection size (upper section) | DN 70 |
| Available cover types | Cover plate; Tileable cover plate |
| Radon-proof certification | Yes — tested and certified |
Article overview
Pumpfix S Underfloor backwater pumping station
Floor slab installation
Floor slab installation
| Picture | Pump | Installation depth | Type of cover | Nominal size (DN) | Length | Width | Backwater protection | Item no. | Show |
|---|---|---|---|---|---|---|---|---|---|
![]() | GTF 500 | 330 mm | Cover plate | 100 | 485 mm | 380 mm | Type 5 | 280451S | Show 280451S |
![]() | GTF 500 | 330 mm | tileable cover plate | 100 | 485 mm | 380 mm | Type 5 | 280451X | Show 280451X |
Shell and Technology Kits Pumpfix S Underfloor
Shell Kit
Shell Kit
| Picture | Pump | Type of cover | Installation situation | Item no. | Show |
|---|---|---|---|---|---|
![]() | Cover plate | 280451S-RBK | Show 280451S-RBK | ||
![]() | tileable cover plate | 280451X-RBK | Show 280451X-RBK |
Technology kit
Technology kit
| Picture | Control unit | Number of pumps | Resistant | Item no. | Show |
|---|---|---|---|---|---|
![]() | 1 | 280451-TK | Show 280451-TK |