Aqualift M Lifting Station

If drainage items are located in the basement, the wastewater often has to be lifted for disposal. The Aqualift M lifting station is the all-in-one solution for basement drainage: it pumps waste water safely and fully automatically above the backwater level into the higher-lying sewer system – even in the event of a pipe burst or flooding, thanks to its integrated drainage function.

Thanks to its compact dimensions, the Aqualift M fits almost anywhere: whether free-standing or with a floor slab installation. One of their particular advantages is that, even after floor slab installation, they can be converted from a mono to a duo system without any problems. This makes them a reliable complete solution for domestic wastewater – flexible, versatile and retrofittable.

Always ready for action: the integrated control unit with SDS (Self-Diagnosis System) features battery backup, continuously checks electrical components, and maintains an electronic operating log. No need to get worked up — installation solutions via the CleverLoop system isolator and CleverVent ventilation valve simplify setup. Perfect timing: the installation kits separate the shell and technology phases, offering flexibility during construction. The shell kit and technology kit can be installed independently. Stay safe: the integrated backwater valve is Radon-proof certified.

Features & benefits

  • Compact dimensions — fits almost anywhere, free-standing or underfloor in floor slab
  • Upgradeable from single (mono) to dual (duo) pump system even after floor slab installation
  • Integrated drainage function protects against pipe burst and flooding
  • Control unit with SDS (Self-Diagnosis System): battery backup, continuous electrical component checks, electronic operating log
  • Compatible with CleverLoop system isolator and CleverVent ventilation valve for simplified installation
  • Shell kit and Technology kit system separates construction phases for flexible installation
  • Integrated backwater valve with Radon-proof certification
  • Suitable for wastewater with and without sewage depending on variant
  • Available with SPZ 1000, GTF 500, or GTF 1200 pumps
  • Standard and chemical-resistant (C) pump variants available
  • Level measurement options: immersion pipe or float switch
  • Cover options: tileable cover plate or black cover
  • Load class K 3 (EN 1253-1) for underfloor versions

Applications

  • Basement drainage — sink, washing machine, and toilet drainage below the backwater level
  • Disposal of domestic wastewater with and without sewage below the sewer level
  • Free-standing installation in exposed drainage pipe systems
  • Underfloor (floor slab) installation in residential buildings
  • Retrofittable installations where future upgrade from single to dual pump is anticipated

Technical specifications

Installation types Exposed (free-standing in drainage pipe) and Underfloor (floor slab)
Wastewater types With sewage (SPZ 1000 pump variants); Without sewage (GTF 500, GTF 1200 pump variants)
Available pumps SPZ 1000, GTF 500, GTF 1200 (each available in standard and chemical-resistant 'C' versions)
System configuration Single station (mono) and Twin pump station (duo)
Cover options (underfloor) Tileable cover plate; Black cover
Load class (underfloor) K 3 per EN 1253-1
Level measurement options Immersion pipe; Float switch
Control unit SDS (Self-Diagnosis System) with battery backup, electrical component monitoring, and electronic operating log
Backwater valve Integrated, Radon-proof certified
Upgrade path Convertible from mono to duo system after floor slab installation

Article overview

Lifting station Aqualift M

Installation in an exposed drainage pipe
Single station
PicturePumpInstallation depthType of wastewaterItem no.Show
28717SPZ 1000with sewage28717Show 28717
28717CSPZ 1000 resistantwith sewage28717CShow 28717C
Twin pump station
PicturePumpInstallation depthType of wastewaterItem no.Show
28718SPZ 1000with sewage28718Show 28718
28718CSPZ 1000 resistantwith sewage28718CShow 28718C

Lifting station Aqualift M Underfloor

Single station
With tileable cover
PictureLoad classPumpType of wastewaterLevel measurement instrumentItem no.Show
28701XK 3 (EN 1253-1)SPZ 1000with sewageImmersion pipe28701XShow 28701X
28701XCK 3 (EN 1253-1)SPZ 1000 resistantwith sewageImmersion pipe28701XCShow 28701XC
280500XK 3 (EN 1253-1)GTF 500without sewageFloat switch280500XShow 280500X
280500XCK 3 (EN 1253-1)GTF 500 resistantwithout sewageFloat switch280500XCShow 280500XC
280550XK 3 (EN 1253-1)GTF 500without sewageImmersion pipe280550XShow 280550X
280550XCK 3 (EN 1253-1)GTF 500 resistantwithout sewageImmersion pipe280550XCShow 280550XC
281200XK 3 (EN 1253-1)GTF 1200without sewageFloat switch281200XShow 281200X
281200XCK 3 (EN 1253-1)GTF 1200 resistantwithout sewageFloat switch281200XCShow 281200XC
281250XK 3 (EN 1253-1)GTF 1200without sewageImmersion pipe281250XShow 281250X
281250XCK 3 (EN 1253-1)GTF 1200 resistantwithout sewageImmersion pipe281250XCShow 281250XC
With black cover
PictureLoad classPumpType of wastewaterLevel measurement instrumentItem no.Show
28701SK 3 (EN 1253-1)SPZ 1000with sewageImmersion pipe28701SShow 28701S
28701SCK 3 (EN 1253-1)SPZ 1000 resistantwith sewageImmersion pipe28701SCShow 28701SC
280500SK 3 (EN 1253-1)GTF 500without sewageFloat switch280500SShow 280500S
280500SCK 3 (EN 1253-1)GTF 500 resistantwithout sewageFloat switch280500SCShow 280500SC
280550SK 3 (EN 1253-1)GTF 500without sewageImmersion pipe280550SShow 280550S
280550SCK 3 (EN 1253-1)GTF 500 resistantwithout sewageImmersion pipe280550SCShow 280550SC
281200SK 3 (EN 1253-1)GTF 1200without sewageFloat switch281200SShow 281200S
281200SCK 3 (EN 1253-1)GTF 1200 resistantwithout sewageFloat switch281200SCShow 281200SC
281250SK 3 (EN 1253-1)GTF 1200without sewageImmersion pipe281250SShow 281250S
281250SCK 3 (EN 1253-1)GTF 1200 resistantwithout sewageImmersion pipe281250SCShow 281250SC
Twin pump station
With tileable cover
PictureLoad classPumpType of wastewaterLevel measurement instrumentItem no.Show
28704XK 3 (EN 1253-1)SPZ 1000with sewageImmersion pipe28704XShow 28704X
28704XCK 3 (EN 1253-1)SPZ 1000 resistantwith sewageImmersion pipe28704XCShow 28704XC
280530XK 3 (EN 1253-1)GTF 500without sewageImmersion pipe280530XShow 280530X
280530XCK 3 (EN 1253-1)GTF 500 resistantwithout sewageImmersion pipe280530XCShow 280530XC
281230XK 3 (EN 1253-1)GTF 1200without sewageImmersion pipe281230XShow 281230X
281230XCK 3 (EN 1253-1)GTF 1200 resistantwithout sewageImmersion pipe281230XCShow 281230XC
With black cover
PictureLoad classPumpType of wastewaterLevel measurement instrumentItem no.Show
28704SK 3 (EN 1253-1)SPZ 1000with sewageImmersion pipe28704SShow 28704S
28704SCK 3 (EN 1253-1)SPZ 1000 resistantwith sewageImmersion pipe28704SCShow 28704SC
280530SK 3 (EN 1253-1)GTF 500without sewageImmersion pipe280530SShow 280530S
280530SCK 3 (EN 1253-1)GTF 500 resistantwithout sewageImmersion pipe280530SCShow 280530SC
281230SK 3 (EN 1253-1)GTF 1200without sewageImmersion pipe281230SShow 281230S
281230SCK 3 (EN 1253-1)GTF 1200 resistantwithout sewageImmersion pipe281230SCShow 281230SC

Shell and Technology Kits Aqualift M Underfloor

Shell Kit
Shell Kit
PicturePumpType of coverInstallation situationItem no.Show
28700S-RBKCover plate with slotted coverfloor slab installation28700S-RBKShow 28700S-RBK
28700X-RBKtileable cover platefloor slab installation28700X-RBKShow 28700X-RBK
280500S-RBKCover plate with slotted coverfloor slab installation280500S-RBKShow 280500S-RBK
280500X-RBKtileable cover platefloor slab installation280500X-RBKShow 280500X-RBK
280501S-RBKCover plate with slotted coverfloor slab installation280501S-RBKShow 280501S-RBK
280501X-RBKtileable cover platefloor slab installation280501X-RBKShow 280501X-RBK
280510S-RBKCover plate with slotted coverfloor slab installation280510S-RBKShow 280510S-RBK
280510X-RBKtileable cover platefloor slab installation280510X-RBKShow 280510X-RBK
280511S-RBKCover plate with slotted coverfloor slab installation280511S-RBKShow 280511S-RBK
280511X-RBKCover plate with slotted coverfloor slab installation280511X-RBKShow 280511X-RBK
Technology kit
Technology kit
PictureControl unitNumber of pumpsResistantItem no.Show
28701-TKComfort128701-TKShow 28701-TK
28701C-TKComfort1Resistant to waste water containing salt, softener and condensate28701C-TKShow 28701C-TK
28704-TKComfort228704-TKShow 28704-TK
28704C-TKComfort2Resistant to waste water containing salt, softener and condensate28704C-TKShow 28704C-TK
280500-TK1280500-TKShow 280500-TK
280500C-TK1Resistant to waste water containing salt, softener and condensate280500C-TKShow 280500C-TK
280530-TKComfort2280530-TKShow 280530-TK
280530C-TKComfort2Resistant to waste water containing salt, softener and condensate280530C-TKShow 280530C-TK
280550-TKComfort1280550-TKShow 280550-TK
280550C-TKComfort1Resistant to waste water containing salt, softener and condensate280550C-TKShow 280550C-TK
281200-TK1281200-TKShow 281200-TK
281200C-TK1Resistant to waste water containing salt, softener and condensate281200C-TKShow 281200C-TK
281230-TKComfort2281230-TKShow 281230-TK
281230C-TKComfort2Resistant to waste water containing salt, softener and condensate281230C-TKShow 281230C-TK
281250-TKComfort1281250-TKShow 281250-TK
281250C-TKComfort1Resistant to waste water containing salt, softener and condensate281250C-TKShow 281250C-TK

Documents & resources