Lifting station Aqualift 100 and 200

The lifting station Aqualift 100 and 200 is the perfect choice for renovations or other installation situations that require an exposed installation. Due to its small installation area, it can also be easily integrated into small rooms by means of retrofitting. Thanks to the one-handed closure that can be operated without tools, maintenance is easy to carry out.

It is available with wastewater tanks in two sizes, as well as different pump capacities. There is also a choice between a single pump with a float or control unit, and two pumps with a control unit. This makes the Aqualift 100 and 200 suitable for a wide variety of applications including the drainage of grease separators. If requirements change, the system can be converted from one to two pumps or another pump type at any time.

Existing premises, little space or an existing pump sump: Flexible drainage solutions that adapt perfectly to the local conditions are required in the case of renovations. The Aqualift 100 and Aqualift 200 are designed precisely for this purpose: Available in two sizes with different pump capacities, suitable for an exposed installation and retrofittable with two pumps.

The Aqualift 100 and 200 Duo with two pumps are ideally suited for applications in which the drainage operation cannot be interrupted. This applies in particular to the drainage of grease separators. The large access cover, which can be opened without tools using one-handed closures, also contributes to the system's reliability.

Features & benefits

  • Tanks with capacity of 100 and 200 litres available
  • Both tanks fit through standard 80 cm wide doorways
  • Retrofittable into most rooms without issue
  • Available with one or two pumps
  • Four pump models to choose from: 650-watt pump in S1 operating mode (continuous operation) with float switch or switchgear; 1.3-kilowatt pump in S3 operating mode (batch operation) with switchgear
  • Both pump types available in resistant versions (resistant to condensate from condensing boilers and brine water)
  • One-handed closure operated without tools
  • Easy maintenance access via large access cover
  • Convertible from single to dual pump system at any time
  • Suitable as sampling chamber when combined with grease separator — no separate sampling chamber installation needed

Applications

  • Basement drainage in apartment blocks with multiple washing machines
  • Renovation installations in existing pump sumps
  • Commercial kitchens with grease separator systems
  • Space-constrained installations
  • Drainage operations requiring continuous, uninterrupted service
  • Grease separator drainage

Article overview

Aqualift 100/200 lifting station

Aqualift 100
Pneumatic level measurement
PicturePumpType of wastewaterType of systemItem no.Show
28513GTF 600without sewageSingle unit28513Show 28513
28514GTF 1250without sewageSingle unit28514Show 28514
28515GTF 600without sewageduo pump28515Show 28515
28516GTF 1250without sewageduo pump28516Show 28516
Mechanical level measurement
PicturePumpType of wastewaterType of systemItem no.Show
28511GTF 600without sewageSingle unit28511Show 28511
28512GTF 1250without sewageSingle unit28512Show 28512
Aqualift 200
Pneumatic level measurement
PicturePumpType of wastewaterType of systemItem no.Show
28517GTF 600without sewageduo pump28517Show 28517
28518GTF 1250without sewageduo pump28518Show 28518

Aqualift 100/200 lifting station resistant

Aqualift 100
Aqualift 100
PicturePumpType of wastewaterType of systemType of level measurementItem no.Show
28511CGTF 600 resistantwithout sewageSingle unitmechanical28511CShow 28511C
28512CGTF 1250 resistantwithout sewageSingle unitmechanical28512CShow 28512C
28513CGTF 600 resistantwithout sewageSingle unitpneumatic28513CShow 28513C
28514CGTF 1250 resistantwithout sewageSingle unitpneumatic28514CShow 28514C
28515CGTF 600 resistantwithout sewageduo pumppneumatic28515CShow 28515C
28516CGTF 1250 resistantwithout sewageduo pumppneumatic28516CShow 28516C
Aqualift 200
Aqualift 200
PicturePumpType of wastewaterType of systemType of level measurementItem no.Show
28517CGTF 600 resistantwithout sewageduo pumppneumatic28517CShow 28517C
28518CGTF 1250 resistantwithout sewageduo pumppneumatic28518CShow 28518C

Documents & resources