Reliable, durable and affordable in price: These properties do not have to be mutually exclusive. This is proven by the Staufix Basic backwater valve. It is the ideal solution to provide protection for individual draining elements such as a shower, washbasin and washing machine which are located below the backwater level.
The Staufix Basic is available as a type 0, 1 and 2. Type 2 has two free-hanging backwater flaps that protect against the ingress of water from the sewer in the event of backwater. In addition, one of these flaps can be manually locked via an emergency closure. The Staufix Basic can be retrofitted.
The Staufix Basic is recommended for protecting individual drainage objects such as a washbasin or washing machine from backflow. It can be easily installed in an exposed position — regardless of whether in a version without, with one or with two backflow flaps.
If a backwater valve no longer fits into the existing pipe, the work and expense can increase. The drop of the Staufix Basic is just 7 mm from the inlet to the drain — so it can be integrated without any problems. The 'Clean out drain body' version can be used as a cleaning piece.
The Staufix Basic is made entirely from polymer — this protects it from corrosion. The practical quick-release closure allows the backwater valve to be opened for tool-free maintenance.
Features & benefits
- Suitable for protecting individual drainage objects (washbasins, washing machines, showers) located below the backwater level
- Easily installed in exposed position
- Available in three types: Type 0 (one flap, no emergency closure), Type 1 (one flap with emergency closure), Type 2 (two flaps with emergency closure)
- Minimal drop of only 7 mm from inlet to drain — integrates seamlessly into existing pipes with minimal height loss
- Clean out drain body version can be used as a cleaning piece
- Constructed entirely from polymer — fully corrosion-resistant
- Tool-free maintenance via practical quick-release closure
- Can be retrofitted into existing installations
- Available with optional rat protection
- For faecal-free wastewater applications
Applications
- Protection of individual drainage objects (showers, washbasins, washing machines) located below the backwater level
- Exposed installation in residential and commercial buildings
- Renovation projects where space constraints exist in existing pipe runs
- Faecal-free wastewater drainage systems
Technical specifications
| Drop from inlet to drain | 7 mm |
|---|---|
| Material | Polymer (fully corrosion-resistant) |
| Available nominal sizes (DN) | DN 100, DN 125, DN 150, DN 200 |
| Types available | Type 0 (no emergency closure), Type 1 (one flap with emergency closure), Type 2 (two flaps with emergency closure) |
| Rat protection option | Available for DN 100, DN 125, DN 150 (Type 1 and Type 2) |
| Installation | Exposed installation; retrofittable |
| Application | Faecal-free wastewater |
| Maintenance | Tool-free via quick-release closure |
Article overview
Staufix Basic backwater valve
With two flaps and emergency closure (Type 2)
With rat protection
| Picture | Nominal size (DN) | Backwater protection | Mechanical backwater flaps | Emergency closure | Item no. | Show |
|---|---|---|---|---|---|---|
![]() | 100 | Type 2 | 2 | yes | 73100R | Show 73100R |
![]() | 125 | Type 2 | 2 | yes | 73125R | Show 73125R |
![]() | 150 | Type 2 | 2 | yes | 73150R | Show 73150R |
Without rat protection
| Picture | Nominal size (DN) | Backwater protection | Mechanical backwater flaps | Emergency closure | Item no. | Show |
|---|---|---|---|---|---|---|
![]() | 100 | Type 2 | 2 | yes | 73100 | Show 73100 |
![]() | 125 | Type 2 | 2 | yes | 73125 | Show 73125 |
![]() | 150 | Type 2 | 2 | yes | 73150 | Show 73150 |
![]() | 200 | Type 2 | 2 | yes | 73200 | Show 73200 |
With one flap and emergency closure (Type 1)
With rat protection
| Picture | Nominal size (DN) | Backwater protection | Mechanical backwater flaps | Emergency closure | Item no. | Show |
|---|---|---|---|---|---|---|
![]() | 100 | Type 1 | 1 | yes | 72100R | Show 72100R |
![]() | 125 | Type 1 | 1 | yes | 72125R | Show 72125R |
![]() | 150 | Type 1 | 1 | yes | 72150R | Show 72150R |
Without rat protection
| Picture | Nominal size (DN) | Backwater protection | Mechanical backwater flaps | Emergency closure | Item no. | Show |
|---|---|---|---|---|---|---|
![]() | 100 | Type 1 | 1 | yes | 72100 | Show 72100 |
![]() | 125 | Type 1 | 1 | yes | 72125 | Show 72125 |
![]() | 150 | Type 1 | 1 | yes | 72150 | Show 72150 |
![]() | 200 | Type 1 | 1 | yes | 72200 | Show 72200 |
![]() | 90 | Type 1 | 1 | yes | 77100 | Show 77100 |
With one flap (Type 0)
With one flap (Type 0)
| Picture | Nominal size (DN) | Backwater protection | Mechanical backwater flaps | Emergency closure | Item no. | Show |
|---|---|---|---|---|---|---|
![]() | 100 | Type 0 | 1 | 71100 | Show 71100 | |
![]() | 125 | Type 0 | 1 | 71125 | Show 71125 | |
![]() | 150 | Type 0 | 1 | 71150 | Show 71150 | |
![]() | 200 | Type 0 | 1 | 71200 | Show 71200 | |
![]() | 90 | Type 0 | 1 | 76100 | Show 76100 |
Cleanout
Cleanout
| Picture | Nominal size (DN) | Backwater protection | Mechanical backwater flaps | Emergency closure | Item no. | Show |
|---|---|---|---|---|---|---|
![]() | 100 | 70100 | Show 70100 | |||
![]() | 125 | 70125 | Show 70125 | |||
![]() | 150 | 70150 | Show 70150 | |||
![]() | 200 | 70200 | Show 70200 |