Practicus Floor Drain

The Practicus project drain is manufactured from high-quality polypropylene (PP) and presents an accessible installation alternative to metal drain systems. Its rust-resistant and smooth surface prevents deposit accumulation, ensuring strong self-cleaning performance. With a drainage capacity of 1.8 l/s, it accommodates showers with high water consumption. The product offers diverse applications in project drainage contexts.

Available in horizontal or vertical outlet configurations across nominal sizes DN 50 to DN 100, the Practicus provides flexible installation options.

Testing conducted by the Fraunhofer Institute confirmed sound-proofing effectiveness, achieving values of ≥ 18 dB(A) per DIN 4109 and ≥ 15 dB(A) per VDI 4100 SST III, demonstrating proven noise reduction against pipe system sounds.

Fire protection compliance is achieved through optional Fire-Kit fire and smoke protection inserts or Quick-Fit pipe penetration seals with integrated fire protection. Upon fire exposure, the protective compound expands automatically, sealing pipe sockets against flames and smoke. Both options fulfill R 120 fire resistance classification.

Features & benefits

  • Manufactured from polypropylene (PP)
  • Rust-resistant surface
  • Smooth interior prevents deposits
  • Strong self-cleaning effect
  • Drainage capacity: 1.8 l/s
  • Suitable for high-volume shower applications
  • Available with horizontal or vertical outlets
  • Nominal sizes: DN 50, DN 70, DN 100
  • Scientifically confirmed sound insulation (≥18 dB(A) DIN 4109; ≥15 dB(A) VDI 4100 SST III)
  • Fire and smoke protection options available
  • R 120 fire resistance rating
  • Multiple mounting flange options (pressure sealing, connection rim, glued)
  • Includes odour trap
  • Load classes K 3 and L 15 (EN 1253-1)
  • Waterproofing layer on upper section
  • Optional enclosed sealing collar per DIN 18534

Applications

  • Project drainage in commercial and residential settings
  • Shower installations
  • Facilities requiring high water throughput
  • Applications with fire protection requirements
  • Noise-sensitive environments

Technical specifications

Material Polypropylene (PP)
Drainage Capacity 1.8 l/s
Outlet Configuration Horizontal or Vertical
Nominal Sizes (DN) 50, 70, 100
Load Classes K 3 (EN 1253-1), L 15 (EN 1253-1)
Sound Insulation (DIN 4109) ≥ 18 dB(A)
Sound Insulation (VDI 4100 SST III) ≥ 15 dB(A)
Fire Resistance Rating R 120
Odour Trap Included
Waterproofing Layer Upper section included

Article overview

Practicus project drain System 125

Vertical outlet
With pressure sealing flange
PictureLoad classNominal size (DN)Odour trapWaterproofing layer on the upper sectionItem no.Show
45219.11K 3 (EN 1253-1)100includedConnection flange45219.11Show 45219.11
45219.51K 3 (EN 1253-1)100includedEnclosed sealing collar to be glued (bd) according to DIN 1853445219.51Show 45219.51
45219.53L 15 (EN 1253-1)100includedEnclosed sealing collar to be glued (bd) according to DIN 1853445219.53Show 45219.53
45219.63L 15 (EN 1253-1)100includedConnection flange45219.63Show 45219.63
45259.11K 3 (EN 1253-1)50includedConnection flange45259.11Show 45259.11
45259.51K 3 (EN 1253-1)50includedEnclosed sealing collar to be glued (bd) according to DIN 1853445259.51Show 45259.51
45259.53L 15 (EN 1253-1)50includedEnclosed sealing collar to be glued (bd) according to DIN 1853445259.53Show 45259.53
45259.63L 15 (EN 1253-1)50includedConnection flange45259.63Show 45259.63
45279.11K 3 (EN 1253-1)70includedConnection flange45279.11Show 45279.11
45279.51K 3 (EN 1253-1)70includedEnclosed sealing collar to be glued (bd) according to DIN 1853445279.51Show 45279.51
45279.53L 15 (EN 1253-1)70includedEnclosed sealing collar to be glued (bd) according to DIN 1853445279.53Show 45279.53
45279.63L 15 (EN 1253-1)70includedConnection flange45279.63Show 45279.63
With glued flange
PictureLoad classNominal size (DN)Odour trapWaterproofing layer on the upper sectionItem no.Show
45218.11K 3 (EN 1253-1)100includedConnection flange45218.11Show 45218.11
PictureLoad classNominal size (DN)Odour trapWaterproofing layer on the upper sectionItem no.Show
45210.11K 3 (EN 1253-1)100includedConnection flange45210.11Show 45210.11
45210.20K 3 (EN 1253-1)100includedConnection flange45210.20Show 45210.20
45210.51K 3 (EN 1253-1)100includedEnclosed sealing collar to be glued (bd) according to DIN 1853445210.51Show 45210.51
45210.53L 15 (EN 1253-1)100includedEnclosed sealing collar to be glued (bd) according to DIN 1853445210.53Show 45210.53
45210.63L 15 (EN 1253-1)100includedConnection flange45210.63Show 45210.63
45250.11K 3 (EN 1253-1)50includedConnection flange45250.11Show 45250.11
45250.20K 3 (EN 1253-1)50includedConnection flange45250.20Show 45250.20
45250.51K 3 (EN 1253-1)50includedEnclosed sealing collar to be glued (bd) according to DIN 1853445250.51Show 45250.51
45250.53L 15 (EN 1253-1)50includedEnclosed sealing collar to be glued (bd) according to DIN 1853445250.53Show 45250.53
45250.63L 15 (EN 1253-1)50includedConnection flange45250.63Show 45250.63
45270.11K 3 (EN 1253-1)70includedConnection flange45270.11Show 45270.11
45270.20K 3 (EN 1253-1)70includedConnection flange45270.20Show 45270.20
45270.51K 3 (EN 1253-1)70includedEnclosed sealing collar to be glued (bd) according to DIN 1853445270.51Show 45270.51
45270.53L 15 (EN 1253-1)70includedEnclosed sealing collar to be glued (bd) according to DIN 1853445270.53Show 45270.53
45270.63L 15 (EN 1253-1)70includedConnection flange45270.63Show 45270.63
Horizontal outlet
With pressure sealing flange
PictureLoad classNominal size (DN)Odour trapWaterproofing layer on the upper sectionItem no.Show
45119.11K 3 (EN 1253-1)100includedConnection flange45119.11Show 45119.11
45119.51K 3 (EN 1253-1)100includedEnclosed sealing collar to be glued (bd) according to DIN 1853445119.51Show 45119.51
45119.53L 15 (EN 1253-1)100includedEnclosed sealing collar to be glued (bd) according to DIN 1853445119.53Show 45119.53
45119.63L 15 (EN 1253-1)100includedConnection flange45119.63Show 45119.63
45159.11K 3 (EN 1253-1)50includedConnection flange45159.11Show 45159.11
45159.51K 3 (EN 1253-1)50includedEnclosed sealing collar to be glued (bd) according to DIN 1853445159.51Show 45159.51
45159.53L 15 (EN 1253-1)50includedEnclosed sealing collar to be glued (bd) according to DIN 1853445159.53Show 45159.53
45159.63L 15 (EN 1253-1)50includedConnection flange45159.63Show 45159.63
45179.11K 3 (EN 1253-1)70includedConnection flange45179.11Show 45179.11
45179.51K 3 (EN 1253-1)70includedEnclosed sealing collar to be glued (bd) according to DIN 1853445179.51Show 45179.51
45179.53L 15 (EN 1253-1)70includedEnclosed sealing collar to be glued (bd) according to DIN 1853445179.53Show 45179.53
45179.63L 15 (EN 1253-1)70includedConnection flange45179.63Show 45179.63
With connection rim
PictureLoad classNominal size (DN)Odour trapWaterproofing layer on the upper sectionItem no.Show
45110.11K 3 (EN 1253-1)100includedConnection flange45110.11Show 45110.11
45110.51K 3 (EN 1253-1)100includedEnclosed sealing collar to be glued (bd) according to DIN 1853445110.51Show 45110.51
45110.53L 15 (EN 1253-1)100includedEnclosed sealing collar to be glued (bd) according to DIN 1853445110.53Show 45110.53
45110.63L 15 (EN 1253-1)100includedConnection flange45110.63Show 45110.63
45150.11K 3 (EN 1253-1)50includedConnection flange45150.11Show 45150.11
45150.51K 3 (EN 1253-1)50includedEnclosed sealing collar to be glued (bd) according to DIN 1853445150.51Show 45150.51
45150.53L 15 (EN 1253-1)50includedEnclosed sealing collar to be glued (bd) according to DIN 1853445150.53Show 45150.53
45150.63L 15 (EN 1253-1)50includedConnection flange45150.63Show 45150.63
45170.11K 3 (EN 1253-1)70includedConnection flange45170.11Show 45170.11
45170.51K 3 (EN 1253-1)70includedEnclosed sealing collar to be glued (bd) according to DIN 1853445170.51Show 45170.51
45170.53L 15 (EN 1253-1)70includedEnclosed sealing collar to be glued (bd) according to DIN 1853445170.53Show 45170.53
45170.63L 15 (EN 1253-1)70includedConnection flange45170.63Show 45170.63

Practicus drain body System 125

Vertical outlet
With pressure sealing flange
PictureNominal size (DN)Odour trapItem no.Show
45219100included45219Show 45219
4525950included45259Show 45259
4527970included45279Show 45279
With connection rim
PictureNominal size (DN)Odour trapItem no.Show
45210100included45210Show 45210
4525050included45250Show 45250
4527070included45270Show 45270
Horizontal outlet
With pressure sealing flange
PictureNominal size (DN)Odour trapItem no.Show
45119100included45119Show 45119
4515950included45159Show 45159
4517970included45179Show 45179
With connection rim
PictureNominal size (DN)Odour trapItem no.Show
45110100included45110Show 45110
4515050included45150Show 45150
4517070included45170Show 45170